Summary for Test 2026-06-26-57-7
Test performed: AASHTO T51-22Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/26/2026 | Sample Unique Key | 57 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/20/2026 | Sample type | Preliminary |
| A brief description of the sample | Tank 04 | The quantity of what the sample constitutes | 1 of 1 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Joshua |
| Last name of sampler or witnessed by | DeLaFuente | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | TK0406262026 | |
| Linked DIME Sample ID | 2026-06-26-52 | The fabricator/manufacturer/facility name | Mojave, CA |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | 4 | |
| Time of sample | HMA Supplier | N/A | |
| Certified Asphalt Supplier | Pacific Asphalt Distribution - Mojave CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | TK0406262026 | |
| HMA Type | N/A | HMA Supplier Mix ID Number | N/A |
Test Details
DIME Sample ID: 2026-06-26-57
DIME Test ID: 2026-06-26-57-7
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2026-08-05
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 08/05/2026
Ductility of test #1 (D1): 115 cm
Ductility of sample: 115 cm
General comments (publicly viewable) (Max 1000 characters): DUCTILITY
Test was verified on 8/5/2026 ✔