Summary for Test 2026-07-29-45-10
Test performed: AASHTO T48-20Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/29/2026 | Sample Unique Key | 45 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/29/2026 |
| Sample type | Quality Control | A brief description of the sample | Tank 5K1 |
| The quantity of what the sample constitutes | 1 of 3, split sample | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | James | Last name of sampler or witnessed by | Saraficio |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 260729-6428M-03 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Coolidge, AZ | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
|---|---|---|---|
| Modified | Yes | Lot number | |
| Sublot number | Tank number | 5K1 | |
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Western Emulsions Incorporated - Coolidge - Coolidge AZ | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | HMA Supplier Mix ID Number |
Test Details
DIME Sample ID: 2026-07-29-45
DIME Test ID: 2026-07-29-45-10
Testing Lab: Western Emulsions, Incorporated - Coolidge
Test Method: AASHTO T48-20: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2026-08-04
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: James Saraficio
Date of test: 08/04/2026
Corrected Flash Point: 307 C
General comments (publicly viewable) (Max 1000 characters): Submitted from ASCP bulk upload.
Test was verified on 8/4/2026 ✔