Summary for Test 2026-07-22-57-1

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 1000697
DEA: 021J75U4
EFIS: 0224000092
DIST-CO-RTE-PM02-LAS-36-14.4/R16.8
Award Date01/23/2025
Closeout DateNot set
Work DescriptionPLACE HMA AND CLASS 2 AB, EXCAVATE ROADWAY, & INSTALL LIGHTING SYSTEM.
Location DescriptionLASSEN COUNTY ABOUT 9 MILES WEST OF SUSANVILLE FROM 1.3 MILES WEST TO 1.2 MILES EAST OF WILLARD CREEK ROAD
QA Service Level1 (Verified on 10/24/2024)

Sample Information

Sample Taken Date07/22/2026 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/22/2026
Sample typeProduction Start-Up A brief description of the sample2 bags RAP
The quantity of what the sample constitutesProduction Start Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byDawn Last name of sampler or witnessed bySloatermen
Title of samplerTET Telephone number of sampler
Laboratory sample identificationD80301B Linked DIME Sample ID
The fabricator/manufacturer/facility nameHat Creek Construction, Ward Lake Plant, Litchfield, CA Transportation Laboratory (TL) Number845876
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceHat Creek Construction and Materials, Ward Lake Facility, Litchfield, CA
Aggregate Size Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix Number

Test Details

DIME Sample ID: 2026-07-22-57
DIME Test ID: 2026-07-22-57-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-08-04

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 07/24/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7330.6 grams
Mass of oven-dry sample in air for Sample 1: 2584.5 grams
Mass of container filled with the sample and water for Sample 1: 8880.7 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.499
Theoretical maximum density at 25°C (77°F): 2491.8 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.499, Gser≈2.705

Test was verified on 8/4/2026