Summary for Test 2026-06-16-22-7
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1001281 DEA: 11430234 EFIS: 1118000029 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-0.1/14.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | REPLACE CONC PVMT, CONSTRUCT AUX LANE & BIKE TRAIL, ELECT, & LANDSCAPE |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO, CHULA VISTA AND NATIONAL CITY FROM 0.3 MILE SOUTH OF ROUTE 805/5 SEPARATION TO ROUTE 805/15 SEPARATION |
| QA Service Level | 1 (Verified on 06/09/2025) |
Sample Information
| Sample Taken Date | 06/16/2026 | Sample Unique Key | 22 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/29/2026 | Sample type | Stock |
| A brief description of the sample | Anchor Bolt F1554 Gr. 55 | The quantity of what the sample constitutes | 840 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Carpenter | Title of sampler | Quality Assurance Inspector |
| Telephone number of sampler | 415-608-1742 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | UIS | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-165-26 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 1201075323 | Nut Mfg. Lot Number(s) | XXX |
| Washer Mfg. Lot Number(s) | XXX | Bolt Specification | F1554 |
| Bolt Length(s) | 5.0' | Nut Specification | XXX |
| Washer Specification | XXX | Finish | HDG |
| Diameter/Size | 2.0" | Bolt Mfg. Lot Number | 120107532320 |
| Rocap Test Requirement(s) | XXX | Lubricant Requirements(s) | XXX |
| Washer Inner Diameter(s) | XXX | Bolt Mill Supplier | Not set |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2026-06-16-22
DIME Test ID: 2026-06-16-22-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-08-04
Test Results
Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/04/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 1201075323 | 2 | 204460 | 0000 | 0000 | yield 141670 | Kleinfelder |
| 2 | 1B | 1201075323 | 2 | 207760 | 0000 | 0000 | yield 144450 | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/4/2026 ✔