Summary for Test 2026-06-25-3-10

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 1000991
DEA: 030J5604
EFIS: 0319000297
DIST-CO-RTE-PM03-PLA,NEV-80-49.3/68.7
Award Date07/11/2025
Closeout DateNot set
Work DescriptionRCP, WSP, AND ELECTRICAL SYSTEMS.
Location DescriptionPLACER AND NEVADA COUNTIES FROM 0.3 MILE EAST OF DRUM FOREBAY OVERCROSSING TO 0.2 MILE EAST OF TROY UNDERCROSSING
QA Service Level1 (Verified on 03/24/2025)

Sample Information

Sample Taken Date06/25/2026 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/07/2026
Sample typeQuality Assurance A brief description of the sampleA325 Hex Bolt
The quantity of what the sample constitutes912 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler8014626352
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUniversal Industrial Sales Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-071-26 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)21039510 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationA325
Bolt Length(s)5" Nut Specificationna
Washer Specificationna FinishMG
Diameter/Size1-1/8" Bolt Mfg. Lot NumberBM1557
Rocap Test Requirement(s)na Lubricant Requirements(s)na
Washer Inner Diameter(s)na

Test Details

DIME Sample ID: 2026-06-25-3
DIME Test ID: 2026-06-25-3-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-08-04

Test Results


Number of Bolt Samples: 3
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/04/2026
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11ABM15571.12510753000000000A325Atlas
21BBM15571.12510823000000000A325Atlas
31CBM15571.12511039000000000A325Atlas

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/4/2026