Summary for Test 2026-07-17-4-1
Test performed: ASTM A775-19Project Information
| Project Identifiers | Project ID: 1001469 DEA: 120K62U4 EFIS: 1224000090 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA,-5-R25.8/30.3 |
| Award Date | 11/12/2025 |
| Closeout Date | Not set |
| Work Description | CONST BRIDGE, RW, SW, PAVEMENT, DRAINAGE, AND ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY IN IRVINE AND TUSTIN FROM YALE AVENUE OVERCROSSING TO ROUTE 5/55 SEPARATION |
| QA Service Level | 1 (Verified on 08/13/2025) |
Sample Information
| Sample Taken Date | 07/17/2026 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/17/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 1.5" x 18" Dowel Baskets |
| The quantity of what the sample constitutes | 3500 Bskts 21,000 LF | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Dsouza |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 9493852715 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Pacific Highway Products | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L132-071-26 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Dowels | Dowel Metal Heat Number | 4400038878, 4400038063 |
|---|---|---|---|
| Dowel Epoxy Batch Number | CH3505AX | Dowel Coating Specification | ASTM A775 |
| Dowel Size | 1.5 in | Dowel Coating Color | Green |
| Dowel Manufacturer | Dowel Coater | SIMCOTE | |
| Release Number | Quality Assurance Code | ||
| Rebar Size (#) |
Test Details
DIME Sample ID: 2026-07-17-4
DIME Test ID: 2026-07-17-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Test Release Date: 2026-08-04
Test Results
Input Type: Calculated
Tester's full name: Andrew Auvinen
Date of test: 08/04/2026
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 40 mils
Bar # for First Bar: 1
Bar # for Second Bar: 2
First Bar Mean: 12.62 mils
Second Bar Mean: 12.04 mils
Total mean value: 12.33 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/4/2026 ✔