Summary for Test 2026-07-22-8-1
Test performed: ASTM A970-18Project Information
| Project Identifiers | Project ID: 1000511 DEA: 06487404 EFIS: 0616000029 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-99-35.8/37.1 |
| Award Date | 01/14/2025 |
| Closeout Date | Not set |
| Work Description | Caldwell Interchange SR99/Ave280 (Visalia) - Replace Bridge Structures and Construct Roundabouts. |
| Location Description | TULARE COUNTY IN AND NEAR VISALIA FROM 0.6 MILE SOUTH OF AVENUE 280 OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 280 OVERCROSSING |
| QA Service Level | 1 (Verified on 08/27/2024) |
Sample Information
| Sample Taken Date | 07/22/2026 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/27/2026 |
| Sample type | Quality Assurance | A brief description of the sample | HRC 555 - Lot 1 and 2 |
| The quantity of what the sample constitutes | HRC 555 - 2 LOTS | From where was the sample collected | Source |
| First name of sampler or witnessed by | NIKHIL | Last name of sampler or witnessed by | MOON |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Pacific Steel Group Napa | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 3500048055 | Head Manufacturer Lot Number(s) | HRC555 |
| Rebar Size | #8 | Headed Bar Model Name | HRC555 |
| Size of Head | Full Size - 9x | Head Connection Type | |
| Head Shape | Circular | Rebar Manufacturer | HRC555 |
| Head Manufacturer | HRC555 | Head Fabricator | HRC555 |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 4FG-17-01 |
Test Details
DIME Sample ID: 2026-07-22-8
DIME Test ID: 2026-07-22-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2026-08-04
Test Results
Number of Headed Bar Samples: 8
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/04/2026
UTM: NA
Temperature: 0 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1/2 | 0.79 | 73000 | 92400 | Ok Necking | WSP |
| 2 | 1/2 | 0.79 | 73435 | 93000 | Ok Necking | WSP |
| 3 | 1/2 | 0.79 | 74680 | 94500 | Ok Necking | WSP |
| 4 | 1/2 | 0.79 | 72590 | 91900 | Ok Necking | WSP |
| 5 | 1/2 | 0.79 | 73880 | 93500 | Ok Necking | WSP |
| 6 | 1/2 | 0.79 | 72470 | 91700 | Ok Necking | WSP |
| 7 | 1/2 | 0.79 | 71320 | 90300 | Ok Necking | WSP |
| 8 | 1/2 | 0.79 | 70830 | 89700 | Ok Necking | WSP |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/4/2026 ✔