Summary for Test 2026-07-21-8-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1001088 DEA: 040Q1204 EFIS: 0418000045 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-280-7.5/7.5 |
| Award Date | 03/05/2026 |
| Closeout Date | Not set |
| Work Description | Polyester Concrete Overlay, RHMA Paving, CMS, and Pedestrian Over-crossing project in San Francisco |
| Location Description | Route 280 |
| QA Service Level | 1 (Verified on 03/21/2025) |
Sample Information
| Sample Taken Date | 07/21/2026 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2026 |
| Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
| The quantity of what the sample constitutes | 150 hoops | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Peter | Last name of sampler or witnessed by | Harvey |
| Title of sampler | Assistant METS Representative | Telephone number of sampler | (707) 364-2452 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Conco Companies Benicia | Transportation Laboratory (TL) Number | TL-6034 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B405-003-26 | Structure unique identifier | 34-0192 |
| Structure name | Farallones Street POC | Bid Item | 3955043 |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 261026 |
| Hoop Manufacturer Lot Number(s) | H02 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #8 |
| Diameter of Hoop | 3'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade Steel Oregon |
| Welding Company | Conco Companies Benicia | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-07-21-8
DIME Test ID: 2026-07-21-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-08-04
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/04/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 2 | 8 | 0.79 | 74710 | 94500 | ok necking | Kleinfelder |
| 2 | 2 | 2 | 8 | 0.79 | 74650 | 94500 | ok necking | Kleinfelder |
| 3 | 3 | 2 | 8 | 0.79 | 73890 | 93500 | affected zone | Kleinfelder |
| 4 | 4 | 2 | 8 | 0.79 | 73290 | 93000 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/4/2026 ✔