Summary for Test 2026-07-07-21-3

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 1001489
DEA: 120K61U4
EFIS: 1224000096
DIST-CO-RTE-PM12-ORA-5-21.3/R25.8
Award DateNot set
Closeout DateNot set
Work DescriptionCONST BRIDGES, RW, SW, OVERLAY, REPLACE SLABS, MODIFY ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN IRVINE FROM ROUTE 5/405 SEPARATION TO YALE AVENUE OVERCROSSING
QA Service Level1 (Verified on 09/08/2025)

Sample Information

Sample Taken Date07/07/2026 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/20/2026
Sample typeQuality Assurance A brief description of the sample7/8" F1554 Gr.55 HDG All Thread
The quantity of what the sample constitutes2 of 6 From where was the sample collectedSource
First name of sampler or witnessed byLorenzo Last name of sampler or witnessed byGarcia
Title of samplerQA Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS Lindon UT Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL115-100-26 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)none
Heat Number(s)8000038347 Nut Mfg. Lot Number(s)none
Washer Mfg. Lot Number(s)none Bolt SpecificationF1554 Gr.55
Bolt Length(s)4-1/2" Nut Specificationnone
Washer Specificationnone FinishHDG
Diameter/Size7/8 Bolt Mfg. Lot Number8000038347
Rocap Test Requirement(s)none Lubricant Requirements(s)none
Washer Inner Diameter(s)none

Test Details

DIME Sample ID: 2026-07-07-21
DIME Test ID: 2026-07-07-21-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-08-04

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 08/03/2026
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A80000383470.8754359000Yield 36930Kleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/4/2026