Summary for Test 2026-06-16-98-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 1002486 DEA: 11930321 EFIS: 0000020717 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/16/2026 | Sample Unique Key | 98 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/23/2026 | Sample type | Per Request |
| A brief description of the sample | Soils | The quantity of what the sample constitutes | 1 Bag |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Allison |
| Last name of sampler or witnessed by | Vonk | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | DS-9 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Unknown | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Job Site | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-06-16-98
DIME Test ID: 2026-06-16-98-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-07-30
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 07/30/2026
| Sieve Size | Cumulative Mass Retained | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 498.8 grams | ||||||
| 0.0 grams | 100 % | |||||
| 23.9 grams | 95 % | |||||
| 71.3 grams | 86 % | |||||
| 151.0 grams | 70 % | |||||
| 225.0 grams | 55 % | |||||
| 296.4 grams | 41 % | |||||
| 367.7 grams | 26 % | |||||
| 424.5 grams | 15 % | |||||
| 428.5 grams | ||||||
General comments (publicly viewable) (Max 1000 characters): Fine Silty Sand
Test was verified on 7/30/2026 ✔