Summary for Test 2026-07-27-4-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1001469 DEA: 120K62U4 EFIS: 1224000090 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA,-5-R25.8/30.3 |
| Award Date | 11/12/2025 |
| Closeout Date | Not set |
| Work Description | CONST BRIDGE, RW, SW, PAVEMENT, DRAINAGE, AND ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY IN IRVINE AND TUSTIN FROM YALE AVENUE OVERCROSSING TO ROUTE 5/55 SEPARATION |
| QA Service Level | 1 (Verified on 08/13/2025) |
Sample Information
| Sample Taken Date | 07/27/2026 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/29/2026 |
| Sample type | Quality Assurance | A brief description of the sample | #7 rebar 5'-0" welded hoops |
| The quantity of what the sample constitutes | 138 hoops | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Joaquin | Last name of sampler or witnessed by | Moreno |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 9095268064 |
| Laboratory sample identification | Linked DIME Sample ID | 2026-07-27-4 | |
| The fabricator/manufacturer/facility name | Martinez steel | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L161-051-26 | Structure unique identifier | |
| Structure name | Bid Item | 3944278 |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 381924 |
| Hoop Manufacturer Lot Number(s) | Lot 3 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #7 |
| Diameter of Hoop | 5'-0" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
| Welding Company | Martinez Steel | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-07-27-4
DIME Test ID: 2026-07-27-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-07-30
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: N Chand
Date of test: 07/29/2026
UTM: NA
Temperature: 72 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 3 | 7 | 0.6 | 56600 | 94500 | visible necking and bar | N Chand |
| 2 | 2 | 3 | 7 | 0.6 | 54900 | 91500 | visible necking and bar | N Chand |
| 3 | 3 | 3 | 7 | 0.6 | 55370 | 92500 | visible necking and bar | N Chand |
| 4 | 4 | 3 | 7 | 0.6 | 54970 | 91500 | visible necking and bar | N Chand |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/30/2026 ✔