Summary for Test 2018-04-24-6-1
Test performed: ASTM A934-13Project Information
| Project Identifiers | Project ID: 212618 DEA: 044G0564 EFIS: 0417000154 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-680-M2.4/M12.4 |
| Award Date | 11/16/2017 |
| Closeout Date | 12/08/2022 |
| Work Description | ROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS |
| Location Description | FREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/16/2017) |
Sample Information
| Sample Taken Date | 04/24/2018 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/27/2018 | Sample type | Retest |
| A brief description of the sample | No.9 A615 Gr. 75 Epoxy Coated Bar | The quantity of what the sample constitutes | 1 Set |
| From where was the sample collected | Source | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Weeks | Title of sampler | QA Inspector |
| Telephone number of sampler | 9512588382 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Williams Form Engineering |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-027-18 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
| Threaded Bar Type | Deformed | Rebar Size | 9 |
| Nut Specification for Threaded Bar | NA | System Manufacturer | WFE |
| Epoxy Coating Color | Purple | Threaded Bar Application | Soil Nail |
| Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | 100790536 |
| Nut Heat Number(s) | Unknown | Bar Lot Number | 10079053621 |
| Nut Lot Number | Unknown | Coupler Heat Number(s) | Unknown |
| Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2018-04-24-6
DIME Test ID: 2018-04-24-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2018-05-08
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 04/30/2018
Lower spec. limit LSL: 10 mils
Upper spec. limit USL: 15 mils
Bar # for First Bar: 1
Bar # for Second Bar: 2
First Bar Side 1 mean value: 15.59
First Bar Side 2 mean value: 14.53
Second Bar Side 1 mean value: 16.43
Second Bar Side 2 mean value: 15.74
First Bar Mean: 15.06
Second Bar Mean: 16.09
Total mean value: 15.57
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/1/2018 ✔