Summary for Test 2018-01-17-7-1

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 211538
DEA: 043G59U4
EFIS: 0415000066
DIST-CO-RTE-PM04-ALA-205-0.0/1.004-Ala-580-0.0/8.0,26.1/30.310-SJ-580-13.5/15.4
Award Date10/24/2016
Closeout Date12/17/2019
Work DescriptionHMA PAVING, REPLACE APPROACH AND PCC SLABS, PRECAST CONCRETE PAVEMENT.
Location DescriptionALAMEDA AND SAN JOAQUIN COUNTIES ON ROUTE 580 FROM PATTERSON PASS ROAD OVERCROSSING TO GREENVILLE ROAD OVERHEAD AND FROM EDEN CANYON ROAD UNDERCROSSING TO STROBRIDGE AVENUE UNDERCROSSING ON ROUTE 205 FROM SAN JOAQUIN COUNTY LINE TO MIDWAY ROAD UNDERCROSSI
QA Service Level1 (Verified on 09/02/2016)

Sample Information

Sample Taken Date01/17/2018 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing04/02/2018 Sample typeAnnual Source Testing
A brief description of the sampleCoarse PCC Aggregate The quantity of what the sample constitutes1 bag
From where was the sample collectedSource First name of sampler or witnessed byRob
Last name of sampler or witnessed byLohman Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identification18-0053
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameGranite Vernalis
Transportation Laboratory (TL) NumberC925313 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-39-0002::VERNALIS
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-01-17-7
DIME Test ID: 2018-01-17-7-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2018-04-27

Test Results


What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Phillip Montes
Date of test: 04/27/2018
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 7.6 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/27/2018 ✔