Summary for Test 2026-07-13-59-3
Test performed: ASTM D5329-20Project Information
| Project Identifiers | Project ID: 995085 DEA: 07322904 EFIS: 0716000059 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-27-0.0/18.6 |
| Award Date | 11/06/2023 |
| Closeout Date | Not set |
| Work Description | REMOVE EXISTING AC PAVEMENT & HMA OVERLAY. |
| Location Description | LOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET |
| QA Service Level | 1 (Verified on 09/11/2023) |
Sample Information
| Sample Taken Date | 07/13/2026 | Sample Unique Key | 59 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/20/2026 | Sample type | Verification |
| A brief description of the sample | Asphalt Rubber Binder | The quantity of what the sample constitutes | 1can |
| From where was the sample collected | Source | First name of sampler or witnessed by | John Mejia |
| Last name of sampler or witnessed by | Mejia | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Sun Valley | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2026-07-13-59
DIME Test ID: 2026-07-13-59-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2026-07-29
Test Results
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 07/28/2026
Temperature: 25 C
Ball Penetration (P1): 5 mm
Final Dial reading (F1): 64 mm
Ball Penetration (P2): 2 mm
Final Dial reading (F2): 60 mm
Ball Penetration (P3): 3 mm
Final Dial reading (F3): 62 mm
Resilience 1: 41 %
Resilience 2: 42 %
Resilience 3: 41 %
Average Resilience: 41 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/29/2026 ✔