Summary for Test 2026-07-24-12-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 1002227
DEA: 051S6304
EFIS: 0525000068
DIST-CO-RTE-PM05-UNKNOWN--unknown
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/08/2026)

Sample Information

Sample Taken Date07/24/2026 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/24/2026
Sample typeAcceptance A brief description of the sampleShoulder Backing
The quantity of what the sample constitutesShoulder Backing From where was the sample collectedJob Site
First name of sampler or witnessed byChris Last name of sampler or witnessed byPalmer
Title of samplerTET Telephone number of sampler
Laboratory sample identification260724-1 Shldr Back- Guerra Linked DIME Sample ID
The fabricator/manufacturer/facility nameGuerra Quarry - Crye Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-40-0007
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedWindrow
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-07-24-12
DIME Test ID: 2026-07-24-12-2
Testing Lab: CT D05 - Paso Robles Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2026-07-27

Test Results


Number of tests: 1
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 07/24/2026
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 12.6
Sand reading (test 1): 3
Sand equivalent (test 1): 24
Sand equivalent before temperature correction: 24
Sand equivalent after temperature correction: 24
General comments (publicly viewable) (Max 1000 characters): Passes 10-35 Spec

Test was verified on 7/27/2026