Summary for Test 2026-06-16-60-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 994675
DEA: 07390204
EFIS: 0722000334
DIST-CO-RTE-PM07-LA-47-0.4 / 2.1
Award Date01/24/2025
Closeout DateNot set
Work DescriptionBridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints.
Location DescriptionRTE 47 between Terminal Island and San Pedro PM 0.4/2.1
QA Service Level1 (Verified on 08/07/2023)

Sample Information

Sample Taken Date06/16/2026 Sample Unique Key60
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/22/2026
Sample typeQuality Assurance A brief description of the sample.6in Prestressing Strand
The quantity of what the sample constitutes2 From where was the sample collectedManufacturer
First name of sampler or witnessed bymike Last name of sampler or witnessed byVasquez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s) Number of Coils
Group Number Strand Diameter
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0513226, S0253273 Mfg. Lot Number(s)S381236-3, S381241-3
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2026-06-16-60
DIME Test ID: 2026-06-16-60-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-07-27

Test Results


Number of Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/27/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0513226S381236-30.2175985957320284.54AEC
2S0253273S381241-30.2175953255324294.5AEC

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/27/2026