Summary for Test 2026-07-07-25-16

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 994675
DEA: 07390204
EFIS: 0722000334
DIST-CO-RTE-PM07-LA-47-0.4 / 2.1
Award Date01/24/2025
Closeout DateNot set
Work DescriptionBridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints.
Location DescriptionRTE 47 between Terminal Island and San Pedro PM 0.4/2.1
QA Service Level1 (Verified on 08/07/2023)

Sample Information

Sample Taken Date07/07/2026 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing07/13/2026 Sample typeQuality Assurance
A brief description of the sample7/8" x 2-3/4" F3125/F1852 A325TC Bolt Assembly The quantity of what the sample constitutes1335
From where was the sample collectedJob Site First name of sampler or witnessed byJayce
Last name of sampler or witnessed byGroves Title of samplerQuailty Assurance Inspector
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameUnytite Inc
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)43738-10977040
Heat Number(s)Bolt 10977040 Nut 256598 Washer B74859 Nut Mfg. Lot Number(s)43617-256598
Washer Mfg. Lot Number(s)43114-B74859 Bolt SpecificationASTM A325
Bolt Length(s)2.75" Nut SpecificationASTM F436
Washer SpecificationASTM A563 FinishMECH Galv
Diameter/Size7/8" Bolt Mfg. Lot Number43738-10977040
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Lub Nut
Washer Inner Diameter(s)938 in Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2026-07-07-25
DIME Test ID: 2026-07-07-25-16
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-07-27

Test Results


Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/27/2026
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A43738-109770400.8757129000TensileKleinfelder
21B43738-109770400.8757351000TensileKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/27/2026 ✔