Summary for Test 2026-06-25-25-1

Test performed: ASTM A722-18

Project Information

Project IdentifiersProject ID: 1000607
DEA: 081K6904
EFIS: 0819000090
DIST-CO-RTE-PM08-RIV-74-5.7/11.8
Award Date01/09/2025
Closeout DateNot set
Work DescriptionROCK EXCAVATION, HMA (TYPE A), RHMA-G, AND CABLE NET DRAPERY SYSTEM.
Location DescriptionRIVERSIDE COUNTY IN AND NEAR LAKE ELSINORE FROM MONTE VISTA STREET TO GRAND AVENUE
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date06/25/2026 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing07/02/2026 Sample typeQuality Assurance
A brief description of the sampleR71 1-3/8” 150 ksi Epoxy Coated All-Thread Bar The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byAlexis
Last name of sampler or witnessed byMillan Title of samplerCT METS QA INSPECTOR
Telephone number of sampler9097569960 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameWilliams Form Eng
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL191-099-26
Structure unique identifier Structure name
Bid Item3913530

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypePlain Rebar Size
Nut Specification for Threaded BarASTM A29 System ManufacturerWilliams Form Eng
Epoxy Coating ColorPurple Threaded Bar ApplicationSoil Nail
Coating StandardsASTM A934 epoxy Bar Heat Number(s)1000225088
Nut Heat Number(s)79013697 Bar Lot Number
Nut Lot Number Coupler Heat Number(s)256637
Coupler Grade1045

Test Details

DIME Sample ID: 2026-06-25-25
DIME Test ID: 2026-06-25-25-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2026-07-27

Test Results


Number of Threaded Bar Samples: 3
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/27/2026
UTM: NA
Temperature: 0 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
111 3/810002250881.48174176000CouplerKleinfelder
221 3/810002250881.481811821508117.90Bar and NutsKleinfelder
331 3/810002250881.48171950136964047Bar and NutsKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/27/2026 ✔