Summary for Test 2026-06-25-19-7

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 1000320
DEA: 11430324
EFIS: 1118000102
DIST-CO-RTE-PM11-SD-805-14.6/23.7
Award Date08/23/2024
Closeout DateNot set
Work DescriptionMODIFY ELECTRICAL, CONCRETE PAVEMENT, DRAINAGE AND SIGNS.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM ROUTE 805/15 SEPARATION TO 0.1 MILE NORTH OF ROUTE 805/52 SEPARATION
QA Service Level1 (Verified on 09/09/2024)

Sample Information

Sample Taken Date06/25/2026 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/07/2026
Sample typeQuality Assurance A brief description of the sampleA325
The quantity of what the sample constitutes1477 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byCarpender
Title of samplerCT METS QA INSPECTOR Telephone number of sampler(415) 608-1742
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUniversal Industrial Sales, Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB24-200-26 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)20964180 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationA325
Bolt Length(s)2" Nut Specificationna
Washer Specificationna FinishMG
Diameter/Size1/2" Bolt Mfg. Lot NumberM6343
Rocap Test Requirement(s)na Lubricant Requirements(s)na
Washer Inner Diameter(s)na

Test Details

DIME Sample ID: 2026-06-25-19
DIME Test ID: 2026-06-25-19-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-07-22

Test Results


Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/22/2026
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AM63430.51987000TensileKleinfelder
21BM63430.51969000TensileKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/22/2026