Summary for Test 2026-07-10-1-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1001361 DEA: 120M9704 EFIS: 1213000099 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-57-11.5/12.5 |
| Award Date | 09/25/2025 |
| Closeout Date | Not set |
| Work Description | CONST BRIDGES, RET WALLS, JPCP, HMA, CONC BARRIERS AND ELECT SYSTEMS. |
| Location Description | ORANGE COUNTY IN ORANGE AND ANAHEIM FROM 0.2 MILE SOUTH OF ORANGEWOOD AVENUE UNDERCROSSING TO KATELLA AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 07/28/2025) |
Sample Information
| Sample Taken Date | 07/10/2026 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/10/2026 |
| Sample type | Quality Assurance | A brief description of the sample | #7 Rebar ASTM A706 GR.60 |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Alexis | Last name of sampler or witnessed by | Millan |
| Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 9097569960 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L191-112-26 | Structure unique identifier | |
| Structure name | Bid Item | 3940210 |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 488725 |
| Hoop Manufacturer Lot Number(s) | 1,5 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #7 |
| Diameter of Hoop | 3'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade Steel |
| Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-07-10-1
DIME Test ID: 2026-07-10-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-07-21
Test Results
Number of Samples: 8
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 07/21/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 7 | 0.60 | 55280 | 92000 | ok necking | Kleinfelder |
| 2 | 2 | 1 | 7 | 0.60 | 54960 | 91500 | ok necking | Kleinfelder |
| 3 | 3 | 1 | 7 | 0.60 | 55470 | 92500 | ok necking | Kleinfelder |
| 4 | 4 | 1 | 7 | 0.60 | 55200 | 92000 | ok necking | Kleinfelder |
| 5 | 1 | 5 | 7 | 0.60 | 57570 | 96000 | ok necking | Kleinfelder |
| 6 | 2 | 5 | 7 | 0.60 | 58660 | 98000 | ok necking | Kleinfelder |
| 7 | 3 | 5 | 7 | 0.60 | 58640 | 97500 | ok necking | Kleinfelder |
| 8 | 4 | 5 | 7 | 0.60 | 60650 | 101000 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/21/2026 ✔