Summary for Test 2026-06-24-20-1
Test performed: ASTM A416-18Project Information
| Project Identifiers | Project ID: 995488 DEA: 051C9504 EFIS: 0513000018 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-R36.0/R37.0 |
| Award Date | 07/09/2024 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PVMT, RHMA, LIGHTING SYSTEMS, AND REPLACE BRIDGES. |
| Location Description | SANTA BARBARA COUNTY ABOUT 8.0 MILES WEST OF GOLETA FROM 0.6 MILE EAST OF REFUGIO ROAD UNDERCROSSING TO 0.4 MILE WEST OF REFUGIO ROAD UNDERCROSSING. |
| QA Service Level | 1 (Verified on 12/11/2023) |
Sample Information
| Sample Taken Date | 06/24/2026 | Sample Unique Key | 20 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/25/2026 |
| Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | mike | Last name of sampler or witnessed by | vasquez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | Number of Coils | ||
| Group Number | Strand Diameter | ||
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | S0253292, S0513426, S0513126, S0513026 | Mfg. Lot Number(s) | S381225-4, S381230-4, S381231-4, S381232-3 |
| Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2026-06-24-20
DIME Test ID: 2026-06-24-20-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-07-21
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 07/21/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | S0253292 | S381225-4 | 0.218 | 61950 | 58140 | 29.3 | 0000 | WSP |
| 2 | S0513426 | S381230-4 | 0.217 | 61460 | 57200 | 28.1 | 0000 | WSP |
| 3 | S0513126 | S381231-4 | 0.217 | 61700 | 57900 | 28.8 | 0000 | WSP |
| 4 | S0513026 | S381232-3 | 0.214 | 61330 | 58570 | 27.6 | 0000 | WSP |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/21/2026 ✔