Summary for Test 2026-07-08-49-1

Test performed: ASTM A416-18
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 1000710
DEA: 100P9244
EFIS: 1023000226
DIST-CO-RTE-PM10-MPA-140-42.0/42.7
Award Date08/22/2025
Closeout DateNot set
Work DescriptionFergusen Slide Rock Avalanche Shed
Location DescriptionMariposa County, along Route 140 in the Merced River canyon, about 8 miles east of Briceburg and 7.6 miles west of El Portal.
QA Service Level1 (Verified on 10/15/2024)

Sample Information

Sample Taken Date07/08/2026 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/13/2026
Sample typeQuality Assurance A brief description of the sample0.600" PT Strand
The quantity of what the sample constitutes8 From where was the sample collectedManufacturer
First name of sampler or witnessed byAlex Last name of sampler or witnessed byPerez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSumiden Texas Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)T301054-5, T301055-7, T301057-4, T301057-6, T301154-1, T301154-4, T301154-5, T350163-6 Number of Coils
Group Number Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)T0243142, T0248309, T0243142 Mfg. Lot Number(s)na
Manufacturer(s)Sumiden Texas

Test Details

DIME Sample ID: 2026-07-08-49
DIME Test ID: 2026-07-08-49-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-07-21

Test Results


Number of Samples: 8
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 07/21/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1T0243142T301054-50.217586005527029.20000Atlas
2T0243142T301055-70.217586005429026.80000Atlas
3T0243142T301057-40.217592905430028.90000Atlas
4T0243142T301057-60.217616005457029.90000Atlas
5T0248309T301154-10.217614705478029.70000Atlas
6T0248309T301154-40.217598005527029.70000Atlas
7T0248309T301154-50.217599305475027.50000Atlas
8T350163-6T350163-60.217583505476029.60000Atlas

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/21/2026

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.