Summary for Test 2026-06-25-70-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 1001194
DEA: 051H4404
EFIS: 0516000074
DIST-CO-RTE-PM05-SB,SLO-1-50.3/50.6,0.0/0.3
Award Date09/30/2025
Closeout DateNot set
Work DescriptionSANTA MARIA RIVER BRIDGE (REPLACE).
Location DescriptionSANTA BARBARA AND SAN LUIS OBISPO COUNTIES IN AND NEAR GUADALUPE AT SANTA MARIA RIVER BRIDGE
QA Service Level1 (Verified on 06/02/2025)

Sample Information

Sample Taken Date06/25/2026 Sample Unique Key70
Date that the sample was received by the laboratory/organization performing the testing06/30/2026 Sample typeQuality Assurance
A brief description of the sample.6in Prestressing Strand The quantity of what the sample constitutes5
From where was the sample collectedFabricator First name of sampler or witnessed byMike
Last name of sampler or witnessed byGonzalez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSumiden Wire
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)S381240-5, S381241-6, S381246-4, S381255-3, S381258-4 Number of Coils
Group Number Strand Diameter
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0513226, S0253273, S0513426, S0253271, S0253779 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2026-06-25-70
DIME Test ID: 2026-06-25-70-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-07-22

Test Results


Number of Samples: 5
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/20/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0513226S381240-50.214606005728029.04.6WSP
2S0253273S381241-60.214607805734028.55.0WSP
3S0513426S381246-40.216622505784029.455.4WSP
4S0253271S381255-30.218610305777029.754.9WSP
5S0253779S381258-40.216617605827029.44.4WSP

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/22/2026 ✔