Summary for Test 2026-04-16-85-7
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 1001910 DEA: 044X5304 EFIS: 0426000087 |
|---|---|
| DIST-CO-RTE-PM | 04-NAP-29-23.54/23.54 |
| Award Date | 10/15/2025 |
| Closeout Date | Not set |
| Work Description | REMOVE AND EXISTING CULVERT AND REPLACE WITH CAST IN PLACE BOX CULVERT AND REPAIR ROADWAY REPLACE CULVERT AND REPAIR ROADWAY |
| Location Description | IN NAPA CO. HWY 29 PM 23.54 |
| QA Service Level | 1 (Verified on 01/16/2026) |
Sample Information
| Sample Taken Date | 04/16/2026 | Sample Unique Key | 85 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/17/2026 | Sample type | Quality Control |
| A brief description of the sample | 4x8 Cylinders | The quantity of what the sample constitutes | 9 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Connor |
| Last name of sampler or witnessed by | Mooneyham | Title of sampler | Field Technician |
| Telephone number of sampler | Laboratory sample identification | 475115E1 Set 1 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Shamrock Materials | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | S/B RTE 29 Wing Wall Trck 2460 | |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 475115E1 |
|---|---|---|---|
| The truck number from where the sample was collected | Load 1 | The batch plant ticket number from where the sample was collected | 0 |
| Concrete batch plant | Shamrock Materials | The fabricator/manufacturer designation for the sample | Set 1 |
| A detailed description of where the material sample was collected | S/B RTE 29 Wing Wall | Where the material sample would have been placed if not sampled | |
| From Lot No. | 1 | Bag Lot No. | 1 |
Test Details
DIME Sample ID: 2026-04-16-85
DIME Test ID: 2026-04-16-85-7
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-09-23
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Valentin Gonzalez
Date of test: 05/14/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 74380 lb
Maximum load on cylinder 2: 77120 lb
Maximum load on cylinder 3: 73860 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 5980 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/23/2026 ✔