Summary for Test 2026-07-08-2-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 1001194
DEA: 051H4404
EFIS: 0516000074
DIST-CO-RTE-PM05-SB,SLO-1-50.3/50.6,0.0/0.3
Award Date09/30/2025
Closeout DateNot set
Work DescriptionSANTA MARIA RIVER BRIDGE (REPLACE).
Location DescriptionSANTA BARBARA AND SAN LUIS OBISPO COUNTIES IN AND NEAR GUADALUPE AT SANTA MARIA RIVER BRIDGE
QA Service Level1 (Verified on 06/02/2025)

Sample Information

Sample Taken Date07/08/2026 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/09/2026
Sample typeQuality Assurance A brief description of the sample#7 ASTM A706 Gr. 60 Rebar
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byAlexis Last name of sampler or witnessed byMillan
Title of samplerCT METS QA INSPECTOR Telephone number of sampler9097569960
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL191-107-26 Structure unique identifier
Structure name Bid Item3924907

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)9013707
Hoop Manufacturer Lot Number(s)1, 5, 10 Material Standard CodeASTM A706
Material Grade60 Rebar Size#7
Diameter of Hoop3'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Arizona
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2026-07-08-2
DIME Test ID: 2026-07-08-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-07-17

Test Results


Number of Samples: 12
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 07/17/2026
UTM: NA
Temperature: 0 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11170.605915098500ok neckingKleinfelder
22170.6062160104000ok neckingKleinfelder
33170.605848097500ok neckingKleinfelder
44170.605947099000ok neckingKleinfelder
51570.605524092000ok neckingKleinfelder
62570.605511092000ok neckingKleinfelder
73570.605493091500ok neckingKleinfelder
84570.605523092000ok neckingKleinfelder
911070.605786096500ok neckingKleinfelder
1021070.605685095000ok neckingKleinfelder
1131070.605583093000ok neckingKleinfelder
1241070.605877098000ok neckingKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/17/2026