Summary for Test 2026-06-09-40-1
Test performed: ASTM A370-20Project Information
| Project Identifiers | Project ID: 1001281 DEA: 11430234 EFIS: 1118000029 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-0.1/14.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | REPLACE CONC PVMT, CONSTRUCT AUX LANE & BIKE TRAIL, ELECT, & LANDSCAPE |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO, CHULA VISTA AND NATIONAL CITY FROM 0.3 MILE SOUTH OF ROUTE 805/5 SEPARATION TO ROUTE 805/15 SEPARATION |
| QA Service Level | 1 (Verified on 06/09/2025) |
Sample Information
| Sample Taken Date | 06/09/2026 | Sample Unique Key | 40 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/22/2026 |
| Sample type | Quality Assurance | A brief description of the sample | Ductile Iron Castings |
| The quantity of what the sample constitutes | 12 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Keith | Last name of sampler or witnessed by | King |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | SDI | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | B166, C176, C186, C266, J225, B126, D096, C18 |
|---|---|---|---|
| Part Number (s) | SDI 19 6 AH SDI 15 6 PC BP SDI 27 6 PC BP SDI | Material Specification | A536 |
| Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar Corporation |
| Prestressing Manufacturer | SDI |
Test Details
DIME Sample ID: 2026-06-09-40
DIME Test ID: 2026-06-09-40-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2026-07-16
Test Results
Number of Samples: 12
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 07/16/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | A216 | 0.506 | 0.201 | 55597 | 98264 | 7 | Kleinfelder |
| 2 | 2 | B056 | 0.505 | 0.200 | 60411 | 104695 | 8 | Kleinfelder |
| 3 | 3 | B126 | 0.502 | 0.198 | 59114 | 105041 | 6 | Kleinfelder |
| 4 | 4 | B166 | 0.506 | 0.201 | 61167 | 106768 | 6 | Kleinfelder |
| 5 | 5 | B266 | 0.506 | 0.201 | 60421 | 103486 | 7 | Kleinfelder |
| 6 | 6 | C176 | 0.506 | 0.201 | 62907 | 113482 | 6 | Kleinfelder |
| 7 | 7 | C186 PO557 | 0.506 | 0.201 | 64150 | 114476 | 6 | Kleinfelder |
| 8 | 8 | C186 PO571 | 0.505 | 0.200 | 59911 | 103397 | 6 | Kleinfelder |
| 9 | 9 | C266 | 0.505 | 0.200 | 63306 | 107790 | 7 | Kleinfelder |
| 10 | 10 | D096 | 0.507 | 0.202 | 57923 | 105283 | 8 | Kleinfelder |
| 11 | 11 | D306 | 0.505 | 0.200 | 58414 | 106093 | 7 | Kleinfelder |
| 12 | 12 | J225 | 0.506 | 0.201 | 58680 | 107216 | 7 | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/16/2026 ✔