Summary for Test 2026-03-13-53-6

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001910
DEA: 044X5304
EFIS: 0426000087
DIST-CO-RTE-PM04-NAP-29-23.54/23.54
Award Date10/15/2025
Closeout DateNot set
Work DescriptionREMOVE AND EXISTING CULVERT AND REPLACE WITH CAST IN PLACE BOX CULVERT AND REPAIR ROADWAY REPLACE CULVERT AND REPAIR ROADWAY
Location DescriptionIN NAPA CO. HWY 29 PM 23.54
QA Service Level1 (Verified on 01/16/2026)

Sample Information

Sample Taken Date03/13/2026 Sample Unique Key53
Date that the sample was received by the laboratory/organization performing the testing03/14/2026 Sample typeQuality Control
A brief description of the sample4x8 Cylinders The quantity of what the sample constitutes15
From where was the sample collectedJob Site First name of sampler or witnessed byJames
Last name of sampler or witnessed byPorter Title of samplerQC Field Technician
Telephone number of sampler Laboratory sample identification475115E1 Set 1
Linked DIME Sample ID The fabricator/manufacturer/facility nameShamrock Materials
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameNorthern Wall
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number475115E1
The truck number from where the sample was collectedLoad 1 The batch plant ticket number from where the sample was collected1028644
Concrete batch plantShamrock Materials The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedNorthern Wall, Truck 2447 Where the material sample would have been placed if not sampled
From Lot No.1 Bag Lot No.1

Test Details

DIME Sample ID: 2026-03-13-53
DIME Test ID: 2026-03-13-53-6
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-07-17

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Travis Van-Y
Date of test: 03/15/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 43770 lb
Maximum load on cylinder 2: 40220 lb
Maximum load on cylinder 3: 41610 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 2 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 3330 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/17/2026 ✔