Summary for Test 2026-06-30-57-1
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 1000481 DEA: 081C07U4 EFIS: 0824000168 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-74-27.5/34.3 |
| Award Date | 08/11/2025 |
| Closeout Date | Not set |
| Work Description | RUBBERIZED HMA, FIBER OPTIC CABLE SYSTEMS, AND COLD PLANE AC PAVEMENT. |
| Location Description | RIVERSIDE COUNTY AT AND NEAR ROMOLAND AND HOMELAND FROM BONNIE DRIVE TO WINCHESTER ROAD |
| QA Service Level | 1 (Verified on 09/02/2024) |
Sample Information
| Sample Taken Date | 06/30/2026 | Sample Unique Key | 57 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/30/2026 |
| Sample type | Acceptance | A brief description of the sample | RHMA-G SP 3/4" |
| The quantity of what the sample constitutes | 762.1 Tons @ 12:33pm | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | MaryAnna | Last name of sampler or witnessed by | Landaverde |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0382G-26 | Linked DIME Sample ID | 2026-06-30-58 |
| The fabricator/manufacturer/facility name | Martin Marietta — Lake Elsinore | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 53418180T3 | |
| Binder content (%) | 7.7 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-06-30-57
DIME Test ID: 2026-06-30-57-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-07-15
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: Kennedy Eubany
Date of test: 07/10/2026
| Cumulative Mass Retained | Correction Factor | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 1993.2 grams | ||||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 39.7 grams | -0.1 % | 98 % | ||||
| 242.3 grams | 0.4 % | 88 % | ||||
| 679.1 grams | 0.5 % | 66 % | ||||
| 1363.8 grams | 0.1 % | 32 % | ||||
| 1596.5 grams | -0.2 % | 20 % | ||||
| 1728.5 grams | -0.3 % | 13 % | ||||
| 1805.9 grams | -0.4 % | 9 % | ||||
| 1856.2 grams | -0.3 % | 7 % | ||||
| 1889.2 grams | -0.2 % | 5 % | ||||
| 1918.0 grams | 0.1 % | 3.9 % | ||||
| 1922.4 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/15/2026 ✔