Summary for Test 2026-06-12-59-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1002057
DEA: 120V2404
EFIS: 1224000109
DIST-CO-RTE-PM12-ORA-405-3.9/23.3
Award Date02/19/2026
Closeout Date10/01/2026
Work DescriptionApply methacrylate, polyester concrete overlay, and deck spall repair.
Location DescriptionORANGE COUNTY AT VARIOUS LOCATIONS FROM UNIVERSITY DRIVE OVERCROSSING TO N405-W22 CONNECTOR SEPARATION
QA Service Level1 (Verified on 04/02/2026)

Sample Information

Sample Taken Date06/12/2026 Sample Unique Key59
Date that the sample was received by the laboratory/organization performing the testing07/14/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byVICTOR
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAAA-Perris
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2026-06-12-59
DIME Test ID: 2026-06-12-59-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-07-15

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Measured
Tester's full name: Hussaya Leelakitrungruang
Date of test: 07/14/2026
Time of test: 8:46 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 75.0 %
Viscosity reading #1 (A) : 0.372 Pa-s
Viscosity reading #2 (B) : 0.375 Pa-s
Viscosity reading #3 (C): 0.38 Pa-s
Average viscosity: 0.376 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/15/2026 ✔