Summary for Test 2026-05-14-80-1
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 1001153 DEA: 081L3104 EFIS: 0820000020 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-74-11.8/17.3 |
| Award Date | 06/06/2025 |
| Closeout Date | Not set |
| Work Description | RHMA (GAP GRADED), REPLACE AC SURF, AND COLD PLANE AC PVMT. |
| Location Description | RIVERSIDE COUNTY IN LAKE ELSINORE FROM GRAND AVENUE TO ROUTE 15/74 SEPARATION |
| QA Service Level | 1 (Verified on 05/05/2025) |
Sample Information
| Sample Taken Date | 05/14/2026 | Sample Unique Key | 80 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/15/2026 |
| Sample type | Acceptance | A brief description of the sample | RHMA-G SP 1/2" |
| The quantity of what the sample constitutes | 750.45 Tons @ 00:33(5/15) | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | RJN | Last name of sampler or witnessed by | Plant QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0232G-26 | Linked DIME Sample ID | 2026-05-14-81 |
| The fabricator/manufacturer/facility name | R.J. Noble Co. — Corona | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 50R003ARSPWEC | |
| Binder content (%) | 7.5 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-05-14-80
DIME Test ID: 2026-05-14-80-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-07-14
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: Maqsud Ahmed
Date of test: 05/26/2026
| Cumulative Mass Retained | Correction Factor | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 1553.4 grams | ||||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 79.1 grams | -0.5 % | 94 % | ||||
| 333.1 grams | -0.4 % | 78 % | ||||
| 1002.0 grams | -0.9 % | 35 % | ||||
| 1249.8 grams | -0.5 % | 19 % | ||||
| 1349.2 grams | -0.2 % | 13 % | ||||
| 1409.8 grams | 0.2 % | 9 % | ||||
| 1452.9 grams | 0.4 % | 7 % | ||||
| 1482.9 grams | 0.5 % | 5 % | ||||
| 1501.4 grams | 0.5 % | 3.8 % | ||||
| 1506.6 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/14/2026 ✔