Summary for Test 2026-07-09-41-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000637
DEA: 031H1404
EFIS: 0316000060
DIST-CO-RTE-PM03-BUT-99-R3.1/5.0
Award Date01/08/2025
Closeout DateNot set
Work DescriptionRHMA, HMA, LIGHTING SYSTEMS, CURB RAMPS, SIDEWALKS, AND DRIVEWAYS.
Location DescriptionBUTTE COUNTY IN AND NEAR GRIDLEY FROM HOLLIS LANE TO 0.2 MILE NORTH OF FORD AVENUE
QA Service Level1 (Verified on 11/06/2024)

Sample Information

Sample Taken Date07/09/2026 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/10/2026
Sample typeQuality Assurance A brief description of the sample3/4" RHMA-G
The quantity of what the sample constitutes2 Boxes From where was the sample collectedSource
First name of sampler or witnessed byBrad Last name of sampler or witnessed byMcKeehan
Title of samplerTET Telephone number of sampler
Laboratory sample identificationDaily Sample 26-123 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Hallwood Transportation Laboratory (TL) NumberC955813
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number5 HMA Mix Number30940532500P
Binder content (%)7.5 Virgin binder PG PG 64-16
Design binder PG PG 64-16 Binder SupplierPNW
RAP content (%)0 WMA AdditivesNo
Antistrip type

Test Details

DIME Sample ID: 2026-07-09-41
DIME Test ID: 2026-07-09-41-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-07-13

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 07/13/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2147.4 g
Mass Loss: 170.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.47 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.48 %
General comments (publicly viewable) (Max 1000 characters): L1 OBC 7.5%

Test was verified on 7/13/2026