Summary for Test 2026-06-16-30-9
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1000611 DEA: 120R32U4 EFIS: 1222000054 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-55-0.2/R17.8 |
| Award Date | 02/07/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE, PLACE RHMA, REPLACE CB, SIGNS AND MODIFY LIGHTING SYSTEM. |
| Location Description | ORANGE COUNTY FROM 0.1 MILE SOUTH OF ROUTE 55/1 SEPARATION IN NEWPORT BEACH TO ROUTE 55/91 SEPARATION IN ANAHEIM |
| QA Service Level | 1 (Verified on 09/30/2024) |
Sample Information
| Sample Taken Date | 06/16/2026 | Sample Unique Key | 30 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/29/2026 |
| Sample type | Stock | A brief description of the sample | 3/4"x 2.0" A325 Bolts |
| The quantity of what the sample constitutes | 4000 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 415-608-1742 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-150-26 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 10942330 | Nut Mfg. Lot Number(s) | xxx |
| Washer Mfg. Lot Number(s) | xxx | Bolt Specification | A325 |
| Bolt Length(s) | 2.0" | Nut Specification | xxx |
| Washer Specification | xxx | Finish | MG |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | BM1485 |
| Rocap Test Requirement(s) | xxx | Lubricant Requirements(s) | xxx |
| Washer Inner Diameter(s) | xxx |
Test Details
DIME Sample ID: 2026-06-16-30
DIME Test ID: 2026-06-16-30-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-07-17
Test Results
Number of Bolt Samples: 3
Input Type: Measured
Tester's full name: Kevin De Souza
Date of test: 07/09/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | BM1485 | 0.75 | 46320 | 0 | 0 | Tensile | Kleinfelder |
| 2 | 2A | BM1485 | 0.75 | 46190 | 0 | 0 | Tensile | Kleinfelder |
| 3 | 3A | BM1485 | 0.75 | 49280 | 0 | 0 | Tensile | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/17/2026 ✔