Summary for Test 2026-05-27-17-10
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1000176 DEA: 034H76U4 EFIS: 0323000040 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-32-5.0/10.2 |
| Award Date | 06/17/2024 |
| Closeout Date | Not set |
| Work Description | REHABILITATE PAVEMENT, INSTALL SIGNAL, LIGHTING, DRAINAGE, & ADA RAMPS |
| Location Description | BUTTE COUNTY IN CHICO FROM MUIR AVENUE TO INTERCHANGE OF STATE ROUTES 99 AND 32 |
| QA Service Level | 1 (Verified on 04/18/2024) |
Sample Information
| Sample Taken Date | 05/27/2026 | Sample Unique Key | 17 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/28/2026 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Bolt |
| The quantity of what the sample constitutes | 765 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Barron |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | AFC Industries | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA |
|---|---|---|---|
| Heat Number(s) | 1000132813 | Nut Mfg. Lot Number(s) | NA |
| Washer Mfg. Lot Number(s) | NA | Bolt Specification | A325 |
| Bolt Length(s) | 3-1/4 | Nut Specification | NA |
| Washer Specification | NA | Finish | HDG |
| Diameter/Size | 1-1/4 | Bolt Mfg. Lot Number | W000316786 |
| Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | NA |
| Washer Inner Diameter(s) | NA |
Test Details
DIME Sample ID: 2026-05-27-17
DIME Test ID: 2026-05-27-17-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-07-09
Test Results
Number of Bolt Samples: 3
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 07/09/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | W000316786 | 1.25 | 128780 | 0000 | 0000 | A325 | Atlas |
| 2 | 1B | W000316786 | 1.25 | 132530 | 0000 | 0000 | A325 | Atlas |
| 3 | 1C | W000316786 | 1.25 | 131280 | 0000 | 0000 | A325 | Atlas |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/9/2026 ✔