Summary for Test 2026-06-16-32-5
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1001281 DEA: 11430234 EFIS: 1118000029 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-0.1/14.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | REPLACE CONC PVMT, CONSTRUCT AUX LANE & BIKE TRAIL, ELECT, & LANDSCAPE |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO, CHULA VISTA AND NATIONAL CITY FROM 0.3 MILE SOUTH OF ROUTE 805/5 SEPARATION TO ROUTE 805/15 SEPARATION |
| QA Service Level | 1 (Verified on 06/09/2025) |
Sample Information
| Sample Taken Date | 06/16/2026 | Sample Unique Key | 32 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/29/2026 |
| Sample type | Stock | A brief description of the sample | F1554 anchor rods |
| The quantity of what the sample constitutes | 100 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 10921080 | Nut Mfg. Lot Number(s) | E18451 |
| Washer Mfg. Lot Number(s) | E18451 | Bolt Specification | xxx |
| Bolt Length(s) | 2.25" | Nut Specification | xxx |
| Washer Specification | xxx | Finish | MG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | E18451 |
| Rocap Test Requirement(s) | xxx | Lubricant Requirements(s) | xxx |
| Washer Inner Diameter(s) | xxx |
Test Details
DIME Sample ID: 2026-06-16-32
DIME Test ID: 2026-06-16-32-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-07-21
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/09/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | E184S1 | 1 | 85670 | 0 | 0 | Tensile | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/21/2026 ✔