Summary for Test 2026-06-11-54-7
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1001625 DEA: 11173704 EFIS: 1100020255 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-2.6/3.2 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | WIDEN INTERCHANGE, STRUCTURES, HMA-A, RHMA-G, LANDSCAPE, & ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF PALM AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 03/04/2026) |
Sample Information
| Sample Taken Date | 06/11/2026 | Sample Unique Key | 54 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/12/2026 |
| Sample type | Production Start-Up | A brief description of the sample | PSU |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Mohammed | Last name of sampler or witnessed by | Masud |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220200 | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | Valero | |
| RAP content (%) | 0 | WMA Additives | No |
| Antistrip type |
Test Details
DIME Sample ID: 2026-06-11-54
DIME Test ID: 2026-06-11-54-7
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-07-10
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 07/09/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 3965.8 g
Mass of the specimen and specimen basket assembly prior to ignition: 5619.5 g
Mass of HMA Sample prior to ignition: 1653.7 g
Mass Loss: 105.4 g
Mass of aggregate remaining after ignition: 1548.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 6.37 %
General comments (publicly viewable) (Max 1000 characters): RAP
Complies
Test was verified on 7/10/2026 ✔
