Summary for Test 2026-07-07-34-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000637 DEA: 031H1404 EFIS: 0316000060 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-99-R3.1/5.0 |
| Award Date | 01/08/2025 |
| Closeout Date | Not set |
| Work Description | RHMA, HMA, LIGHTING SYSTEMS, CURB RAMPS, SIDEWALKS, AND DRIVEWAYS. |
| Location Description | BUTTE COUNTY IN AND NEAR GRIDLEY FROM HOLLIS LANE TO 0.2 MILE NORTH OF FORD AVENUE |
| QA Service Level | 1 (Verified on 11/06/2024) |
Sample Information
| Sample Taken Date | 07/07/2026 | Sample Unique Key | 34 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/08/2026 |
| Sample type | Production Start-Up | A brief description of the sample | 3/4" RHMA-G |
| The quantity of what the sample constitutes | 12 Boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Brad | Last name of sampler or witnessed by | McKeehan |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | PSU 26-118 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Teichert Hallwood | Transportation Laboratory (TL) Number | C955811 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | 30940532500P |
| Binder content (%) | 7.5 | Virgin binder PG | PG 64-16 |
| Design binder PG | PG 64-16 | Binder Supplier | PNW |
| RAP content (%) | 0 | WMA Additives | No |
| Antistrip type |
Test Details
DIME Sample ID: 2026-07-07-34
DIME Test ID: 2026-07-07-34-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-07-08
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 07/08/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2119.9 g
Mass Loss: 166.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.47 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.37 %
General comments (publicly viewable) (Max 1000 characters): L1
OBC 7.5%
Test was verified on 7/8/2026 ✔