Summary for Test 2026-06-16-23-3
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 995026 DEA: 040Q1004 EFIS: 0418000044 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-580-20.7/30.8 |
| Award Date | 07/11/2024 |
| Closeout Date | Not set |
| Work Description | REHAB ALA 580 |
| Location Description | ALAMEDA COUNTY IN PLEASANTON AND CASTRO VALLEY FROM ROUTE 680/580 SEPARATION TO ROUTE 580/238 SEPARATION |
| QA Service Level | 1 (Verified on 07/28/2023) |
Sample Information
| Sample Taken Date | 06/16/2026 | Sample Unique Key | 23 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/29/2026 | Sample type | Stock |
| A brief description of the sample | 3/4"x 8" F1554 all thread rods | The quantity of what the sample constitutes | 100 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Carpenter | Title of sampler | Quality Assurance Inspector |
| Telephone number of sampler | 415-608-1742 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | UIS | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-160-26 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 1201048948 | Nut Mfg. Lot Number(s) | xxx |
| Washer Mfg. Lot Number(s) | xxx | Bolt Specification | F1554 |
| Bolt Length(s) | 8.0" | Nut Specification | xxx |
| Washer Specification | xxx | Finish | HDG |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 1201048948 |
| Rocap Test Requirement(s) | xxx | Lubricant Requirements(s) | xxx |
| Washer Inner Diameter(s) | xxx | Bolt Mill Supplier | Not set |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2026-06-16-23
DIME Test ID: 2026-06-16-23-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-07-09
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/08/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 120104894860 | 0.75 | 24285 | 0 | 0 | Tensile | WSP |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/9/2026 ✔