Summary for Test 2026-06-10-8-5
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1001360 DEA: 09374804 EFIS: 0918000020 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-395-115.0 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | BUILDING WORK AND PLACE HMA (TYPE A). |
| Location Description | INYO COUNTY IN BISHOP AT THE DISTRICT OFFICE AT 500 SOUTH MAIN STREET |
| QA Service Level | 1 (Verified on 07/09/2025) |
Sample Information
| Sample Taken Date | 06/10/2026 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/23/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2"-13 X 1.25" |
| The quantity of what the sample constitutes | 155 | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | JAYCE | Last name of sampler or witnessed by | GROVES |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cordova Bolt Inc. Buena Park, CA. | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 10951300 1000232158 190158320 | Nut Mfg. Lot Number(s) | W000302829 |
| Washer Mfg. Lot Number(s) | 1025-824 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 1.25" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | Black |
| Diameter/Size | 1/2" | Bolt Mfg. Lot Number | E177U1 |
| Rocap Test Requirement(s) | No | Lubricant Requirements(s) | Yes |
| Washer Inner Diameter(s) | half inch |
Test Details
DIME Sample ID: 2026-06-10-8
DIME Test ID: 2026-06-10-8-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-07-09
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/08/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | E177U1 | 0.5 | 19280 | 0 | 0 | Bolt Tensile | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/9/2026 ✔