Summary for Test 2026-06-30-17-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1001324
DEA: 061E8804
EFIS: 0622000111
DIST-CO-RTE-PM06-FRE-180-24.6/41.1,43.8/53.3
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane, HMA paving and pavement delineation.
Location DescriptionFRESNO COUNTY IN AND NEAR KERMAN FROM BELMONT AVENUE TO MODOC AVENUE AND FROM 0.2 MILE EAST OF GOLDENROD AVENUE TO 0.3 MILE WEST OF BRAWLEY AVENUE
QA Service Level1 (Verified on 06/23/2025)

Sample Information

Sample Taken Date06/30/2026 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/30/2026
Sample typeAcceptance A brief description of the sample1/2" HMA
The quantity of what the sample constitutes8 Boxes HMA From where was the sample collectedSource
First name of sampler or witnessed byTomas Last name of sampler or witnessed bySilva
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Madera Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number1
Sublot number4 HMA Mix Number
Binder content (%)4.4 Virgin binder PG PG 70-10
Design binder PG Binder SupplierSJR
RAP content (%)15 WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-06-30-17
DIME Test ID: 2026-06-30-17-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-07-08

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 07/01/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 2929.8 g
Mass of the specimen and specimen basket assembly prior to ignition: 4744.1 g
Mass of HMA Sample prior to ignition: 1814.3 g
Mass Loss: 90.8 g
Mass of aggregate remaining after ignition: 1723.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.53 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.17 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.30 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/8/2026