Summary for Test 2026-06-02-106-6
Test performed: AASHTO T315-22Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/02/2026 | Sample Unique Key | 106 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/02/2026 | Sample type | Quality Control |
| A brief description of the sample | PG58-16 | The quantity of what the sample constitutes | 1 of 2 cans |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | RICK |
| Last name of sampler or witnessed by | RAMOS | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 5816260602 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | San Joaquin Refinery, Bakersfield, CAopop | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-16 |
|---|---|---|---|
| Modified | No | Lot number | 5816260602 |
| Sublot number | Tank number | 2002 | |
| Time of sample | 10:00 | HMA Supplier | |
| Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | Yes |
| Multigrade Type | PG 58-22 / PG 58-16 | Asphalt Binder Mix Number | |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2026-06-02-106
DIME Test ID: 2026-06-02-106-6
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2026-07-07
Test Results
Phase: PAV residue
Input Type: Calculated
Tester's full name: CHRIS FLORENCE
Date of test: 06/03/2026
Test Plate Diameter: 8 mm
Phase Angle (δ) (for the 10 cycles): 58.6 degree
(G*) x sin(δ)=: 4050 kPa
General comments (publicly viewable) (Max 1000 characters): TEST@25.0C
Test was verified on 7/7/2026 ✔