Summary for Test 2026-06-26-41-8

Test performed: AASHTO T30-25

Project Information

Project IdentifiersProject ID: 1001609
DEA: 040AA244
EFIS: 0419000455
DIST-CO-RTE-PM04-CC, -680-R0.0/R7.7
Award Date12/18/2025
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT, COLD PLAN AC PVMT, GRIND EXIST CONC PVMT.
Location DescriptionCONTRA COSTA COUNTY IN SAN RAMON AND DANVILLE FROM THE ALAMEDA COUNTY LINE TO 0.2 MILE NORTH OF DIABLO ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/06/2025)

Sample Information

Sample Taken Date06/26/2026 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/29/2026
Sample typeAcceptance A brief description of the sample3/4"HMA w/25% RAP
The quantity of what the sample constitutes750 Tons From where was the sample collectedSource
First name of sampler or witnessed byDennis Last name of sampler or witnessed byYeung
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-06-26-41
DIME Test ID: 2026-06-26-41-8
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-07-07

Test Results


Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Has the fine aggregate sample been reduced?: No
Is an aggregate correction factor used?: Yes
Was the aggregate obtained using ASTM D8159?: No
Input Type: Measured
Tester's full name: Robert Lohman
Date of test: 07/07/2026
Total mass of material in the sample: 2036.5 grams
Cumulative mass retained on the 2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 in. sieve: 0.0 grams
Cumulative mass retained on the 3/4 in. sieve: 13.2 grams
Cumulative mass retained on the 1/2 in. sieve: 238.3 grams
Cumulative mass retained on the 3/8 in. sieve: 448.5 grams
Cumulative mass retained on the #4 sieve: 1040.8 grams
Cumulative mass retained on the #8 sieve: 1432.9 grams
Cumulative mass retained on the #16 sieve: 1638.0 grams
Cumulative mass retained on the #30 sieve: 1744.7 grams
Cumulative mass retained on the #50 sieve: 1821.9 grams
Cumulative mass retained on the #100 sieve: 1890.6 grams
Cumulative mass retained on the #200 sieve: 1934.6 grams
Cumulative mass retained on the pan: 1962.8 grams
Aggregate correction factor for the 2 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 1 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 3/4 in. sieve (% passing): 0.3 %
Aggregate correction factor for the 1/2 in. sieve (% passing): 0.6 %
Aggregate correction factor for the 3/8 in. sieve (% passing): 3.1 %
Aggregate correction factor for the #4 sieve (% passing): 2.8 %
Aggregate correction factor for the #8 sieve (% passing): 1.7 %
Aggregate correction factor for the #16 sieve (% passing): 2.0 %
Aggregate correction factor for the #30 sieve (% passing): 1.8 %
Aggregate correction factor for the #50 sieve (% passing): 1.5 %
Aggregate correction factor for the #100 sieve (% passing): 1.2 %
Aggregate correction factor for the #200 sieve (% passing): 1.0 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 89 %
Cumulative percent passing the 3/8 in. sieve: 81 %
Cumulative percent passing the #4 sieve: 52 %
Cumulative percent passing the #8 sieve: 31 %
Cumulative percent passing the #16 sieve: 22 %
Cumulative percent passing the #30 sieve: 16 %
Cumulative percent passing the #50 sieve: 12 %
Cumulative percent passing the #100 sieve: 8 %
Cumulative percent passing the #200 sieve: 6.0 %
General comments (publicly viewable) (Max 1000 characters): Lot 1 SL. 12

Test was verified on 7/7/2026