Summary for Test 2026-05-21-77-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000513
DEA: 020J8504
EFIS: 0219000168
DIST-CO-RTE-PM02-SIS-89-21/R34.622
Award Date08/05/2025
Closeout DateNot set
Work DescriptionMCCLOUD CAPM - PAVEMENT REHABILITATION
Location DescriptionIN SISKIYOU COUNTY AT AND NEAR MCCLOUD FROM 0.1 MILE SOUTH OF MUD CREEK BRIDGE TO ROUTE 5
QA Service Level1 (Verified on 08/12/2024)

Sample Information

Sample Taken Date05/21/2026 Sample Unique Key77
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/01/2026
Sample typeAcceptance A brief description of the sample1 box of Lime Treated 1/2-inch Type A HMA (eq. PG 64-16)
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byGiuliano Last name of sampler or witnessed byGiuntoli
Title of sampler Telephone number of sampler
Laboratory sample identificationD80216 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis — Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number877625
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number1
Sublot number HMA Mix Number2603004
Binder content (%)5.2 Virgin binder PGPG 58-22
Design binder PG PG 64-16 Binder SupplierAlbina (Klamath Falls, OR)
RAP content (%)25 WMA AdditivesNo
Antistrip typeLime

Test Details

DIME Sample ID: 2026-05-21-77
DIME Test ID: 2026-05-21-77-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-07-06

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Ward Jenkins
Date of test: 07/01/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 3020.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 4626.8 g
Mass of HMA Sample prior to ignition: 1606.8 g
Mass Loss: 94.1 g
Mass of aggregate remaining after ignition: 1512.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.59 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.08 %
General comments (publicly viewable) (Max 1000 characters): Pb=5.40%

Test was verified on 7/6/2026