Summary for Test 2026-07-01-5-1
Test performed: AASHTO T209-25Project Information
| Project Identifiers | Project ID: 1001564 DEA: 030J4104 EFIS: 0319000281 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA-80-33.0/44.9 |
| Award Date | 07/01/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PVMT, HMA, CLASS 2 AB, RDWY EXC, MGS, & RCP. |
| Location Description | PLACER COUNTY IN AND NEAR COLFAX FROM 0.1 MILE WEST OF ROUTE 174/80 SEPARATION TO 0.1 MILE EAST OF ALTA ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 09/17/2025) |
Sample Information
| Sample Taken Date | 07/01/2026 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/01/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 HMA-A SP R25 PG 58-22 | The quantity of what the sample constitutes | 2 Boxes HMA-A |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Dustan |
| Last name of sampler or witnessed by | Kliethermes | Title of sampler | Materials Tester |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Hallwood | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 17 | HMA Mix Number | 30940132416P |
| Binder content (%) | 4.5 | Virgin binder PG | |
| Design binder PG | PG 58-22 | Binder Supplier | PNW |
| RAP content (%) | 25 | WMA Additives | No |
| Antistrip type |
Test Details
DIME Sample ID: 2026-07-01-5
DIME Test ID: 2026-07-01-5-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-07-02
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: KHUE YANG
Date of test: 07/02/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7402.5 grams
Mass of oven-dry sample in air for Sample 1: 2633.6 grams
Mass of container filled with the sample and water for Sample 1: 9021.3 grams
Temperature of Water: 25 °F
Specific Gravity for Sample 1: 2.595
Theoretical maximum density at 25°C (77°F): 2587 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/2/2026 ✔