Summary for Test 2026-06-04-134-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 994418
DEA: 040J5504
EFIS: 0414000012
DIST-CO-RTE-PM04-ALA-84-17.2/17.2
Award Date02/03/2026
Closeout DateNot set
Work DescriptionREPLACE BRIDGE, WIDEN ROADWAY, & CONSTRUCT SIDEWALKS.
Location DescriptionALAMEDA COUNTY AT SUNOL FROM SILVER SPRING ROAD UNDERPASS TO PLEASANTON SUNOL ROAD
QA Service Level1 (Verified on 12/01/2022)

Sample Information

Sample Taken Date06/04/2026 Sample Unique Key134
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/08/2026
Sample typeQuality Assurance A brief description of the samplePCC with Addmixture
The quantity of what the sample constitutes24.0 yrd^3 From where was the sample collectedFabricator
First name of sampler or witnessed byTamim Last name of sampler or witnessed byNasimi
Title of samplerQC Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKie-Con Antioch Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid Item3938242

Material Information

Material TypePrecast Concrete The concrete mix design numberKMS-9025S05C
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected127560
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedTuckerBilt Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-06-04-134
DIME Test ID: 2026-06-04-134-1
Testing Lab: CT HQ - Vallejo Field Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2026-07-02

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Daniel Arreola
Date of test: 07/02/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1: 9 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 118610 lb
Maximum load on cylinder 2: 103985 lb
Maximum load on cylinder 3: 77795 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 0 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 9440.0 psi
Compressive strength of cylinder 2: 8270.0 psi
Compressive strength of cylinder 3: 6190 psi
Compressive strength (to nearest 10 psi): 7970 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters): Design 4 kips

Test was verified on 7/2/2026