Summary for Test 2026-05-20-115-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 214649 DEA: 07316004 EFIS: 0715000194 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-14-60.70 |
| Award Date | 02/07/2023 |
| Closeout Date | Not set |
| Work Description | REHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES. |
| Location Description | ROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE. |
| QA Service Level | 1 (Verified on 01/29/2020) |
Sample Information
| Sample Taken Date | 05/20/2026 | Sample Unique Key | 115 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/20/2026 | Sample type | Quality Assurance |
| A brief description of the sample | JPCP | The quantity of what the sample constitutes | 5 CY of 10 CY |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Jareerattana |
| Last name of sampler or witnessed by | Sirisujarittham | Title of sampler | Field Technician |
| Telephone number of sampler | 562-564-9465 | Laboratory sample identification | 26-1779 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Atkinson - Lancaster Batch Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SCI-12622-3 |
|---|---|---|---|
| The truck number from where the sample was collected | 7 | The batch plant ticket number from where the sample was collected | 7 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Loader Chute | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-05-20-115
DIME Test ID: 2026-05-20-115-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-07-02
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jareerattana Sirisujarittham
Date of test: 07/01/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.96 in
Average diameter of cylinder 3: 5.99 in
Maximum load on cylinder 1: 158095 lb
Maximum load on cylinder 2: 158435 lb
Maximum load on cylinder 3: 160555 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 42 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 27.9 in^2
Cross sectional area of cylinder 3: 28.18 in^2
Compressive strength (to nearest 10 psi): 5670 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/2/2026 ✔