Summary for Test 2026-06-11-26-6

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 1000481
DEA: 081C07U4
EFIS: 0824000168
DIST-CO-RTE-PM08-RIV-74-27.5/34.3
Award Date08/11/2025
Closeout DateNot set
Work DescriptionRUBBERIZED HMA, FIBER OPTIC CABLE SYSTEMS, AND COLD PLANE AC PAVEMENT.
Location DescriptionRIVERSIDE COUNTY AT AND NEAR ROMOLAND AND HOMELAND FROM BONNIE DRIVE TO WINCHESTER ROAD
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date06/11/2026 Sample Unique Key26
Date that the sample was received by the laboratory/organization performing the testing06/16/2026 Sample typeVerification
A brief description of the sampleJMF 3/4 HMA -A-SP R25% LAS 0.5% The quantity of what the sample constitutes4 Bags of Combined Aggregate, 2 Bags of Combined RAP
From where was the sample collectedManufacturer First name of sampler or witnessed byDylan
Last name of sampler or witnessed byNault Title of sampler
Telephone number of sampler Laboratory sample identification0332A-26
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartin Mariatta
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0098
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number53417195T3 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-06-11-26
DIME Test ID: 2026-06-11-26-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2026-07-21

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: DP
Date of test: 06/23/2026
Bulk dry specific gravity: 2.589
Average uncompacted voids: 47.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/21/2026 ✔