Summary for Test 2026-06-18-8-1

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 1001686
DEA: 11430264
EFIS: 1118000083
DIST-CO-RTE-PM11-SD-94,188-15.2/65.3,0.0/1.9
Award DateNot set
Closeout DateNot set
Work DescriptionDRAINAGE RESTORATION, ADA CURB RAMPS & COMPLETE STREET.
Location DescriptionSAN DIEGO COUNTY ABOUT 6 MILES EAST OF LEMON GROVE ON ROUTE 94 FROM SWEETWATER RIVER BRIDGE TO AVENUE DE ROBLES VERDES NEAR MANZANITA AND ON ROUTE 188 FROM MEXICO BORDER NEAR TECATE TO ROUTE 94.
QA Service Level1 (Verified on 02/05/2026)

Sample Information

Sample Taken Date06/18/2026 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing06/18/2026 Sample typeVerification
A brief description of the sampleJMFV The quantity of what the sample constitutes12 boxes
From where was the sample collectedSupplier First name of sampler or witnessed byEddie
Last name of sampler or witnessed byBidinger Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID2026-06-18-13 The fabricator/manufacturer/facility nameMartin Marietta Lakeside
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number23417095
Binder content (%)4.5 Virgin binder PG PG 64-16
Design binder PG PG 64-16 Binder SupplierWorld Oil
RAP content (%)23 WMA AdditivesNo
Antistrip typeMorelife 5000

Test Details

DIME Sample ID: 2026-06-18-8
DIME Test ID: 2026-06-18-8-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-07-01

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 06/30/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7475.6 grams
Mass of oven-dry sample in air for Sample 1: 2559.6 grams
Mass of container filled with the sample and water for Sample 1: 9022.6 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.528
Theoretical maximum density at 25°C (77°F): 157.4 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): Complies Target 2.512 Tested 2.528

Test was verified on 7/1/2026 ✔