Summary for Test 2026-05-29-57-6

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 215734
DEA: 024H0104
EFIS: 0218000068
DIST-CO-RTE-PM02-PLU-70-78.3/90.3
Award Date01/29/2025
Closeout DateNot set
Work DescriptionREPLACE AC SURFACING, PLACE HMA AND THERMOPLASTIC TRAFFIC STRIPING.
Location DescriptionPLUMAS COUNTY NEAR PORTOLA FROM 0.4 MILE WEST OF BIG GRIZZLY CREEK BRIDGE TO 0.8 MILE WEST OF SUMMIT SCHOOL DRIVE
QA Service Level1 (Verified on 07/08/2021)

Sample Information

Sample Taken Date05/29/2026 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/16/2026
Sample typeAcceptance A brief description of the sample2 cans of binder
The quantity of what the sample constitutes2, 1 quart cans of binder From where was the sample collectedSource
First name of sampler or witnessed byE Last name of sampler or witnessed byChavez
Title of samplerMaterials Tester Telephone number of sampler
Laboratory sample identification080217 Linked DIME Sample ID
The fabricator/manufacturer/facility nameHat Creek Construction, Ward Lake Plant, Litchfield, CA Transportation Laboratory (TL) Number036633
Inspector Lot Number from the Transportation Laboratory (TL) Form036633 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA SupplierHat Creek- Yard Lake
Certified Asphalt SupplierWestern Emulsions - White City Emulsion Plant - White City OR MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2026-05-29-57
DIME Test ID: 2026-05-29-57-6
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-06-30

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: No
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 06/30/2026
Any material loss from containers during heating process/testing?: no data
Mass of container #1 before test (m1i): 211.932 grams
Mass of container #2 before test (m2i): 212.217 grams
Mass of container #1 after test (m1f): 211.761 grams
Mass of container #2 after test (m2f): 212.045 grams
Mass of empty container #1: 176.731 grams
Mass of empty container #2: 177.216 grams
Average mass change: -0.489 percent
General comments (publicly viewable) (Max 1000 characters): MASS CHANGE

Test was verified on 6/30/2026