Summary for Test 2026-06-16-4-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1001723 DEA: 050N7064 EFIS: 0524000077 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-10.9/12.3 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | SB 101 - Segment 4E North - Cabrillo |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/03/2025) |
Sample Information
| Sample Taken Date | 06/16/2026 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/19/2026 | Sample type | Quality Assurance |
| A brief description of the sample | #7, 3'-8" Welded Hoops | The quantity of what the sample constitutes | 8 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Alexis |
| Last name of sampler or witnessed by | Millan | Title of sampler | CT METS QA INSPECTOR |
| Telephone number of sampler | 9097569960 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | RKR Steel Welding | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L191-089-26 | |
| Structure unique identifier | Structure name | ||
| Bid Item | 3948751 |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 9012357 |
| Hoop Manufacturer Lot Number(s) | 1, 4 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #7 |
| Diameter of Hoop | 3'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel AZ |
| Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-06-16-4
DIME Test ID: 2026-06-16-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-06-30
Test Results
Number of Samples: 8
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 06/30/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 7 | 0.60 | 56750 | 94500 | ok necking | Kleinfelder |
| 2 | 2 | 1 | 7 | 0.60 | 56800 | 94500 | ok necking | Kleinfelder |
| 3 | 3 | 1 | 7 | 0.60 | 57570 | 96000 | ok necking | Kleinfelder |
| 4 | 4 | 1 | 7 | 0.60 | 57440 | 95500 | ok necking | Kleinfelder |
| 5 | 1 | 4 | 7 | 0.60 | 57460 | 96000 | ok necking | Kleinfelder |
| 6 | 2 | 4 | 7 | 0.60 | 57770 | 96500 | ok necking | Kleinfelder |
| 7 | 3 | 4 | 7 | 0.60 | 62240 | 104000 | ok necking | Kleinfelder |
| 8 | 4 | 4 | 7 | 0.60 | 57870 | 96500 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/30/2026 ✔