Summary for Test 2026-05-18-74-2

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 215734
DEA: 024H0104
EFIS: 0218000068
DIST-CO-RTE-PM02-PLU-70-78.3/90.3
Award Date01/29/2025
Closeout DateNot set
Work DescriptionREPLACE AC SURFACING, PLACE HMA AND THERMOPLASTIC TRAFFIC STRIPING.
Location DescriptionPLUMAS COUNTY NEAR PORTOLA FROM 0.4 MILE WEST OF BIG GRIZZLY CREEK BRIDGE TO 0.8 MILE WEST OF SUMMIT SCHOOL DRIVE
QA Service Level1 (Verified on 07/08/2021)

Sample Information

Sample Taken Date05/18/2026 Sample Unique Key74
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/22/2026
Sample typeProduction Start-Up A brief description of the sample16 boxes of Lime Treated 1/2-inch Type A HMA (eq. PG 64-16)
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byEmilio Last name of sampler or witnessed byChavez
Title of sampler Telephone number of sampler
Laboratory sample identificationD80211 Linked DIME Sample ID
The fabricator/manufacturer/facility nameHat Creek Construction & Materials — Ward Lake Plant (Litchfield, CA) Transportation Laboratory (TL) Number036629
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number2307P04
Binder content (%)6.2 Virgin binder PGPG 58-22
Design binder PG PG 64-16 Binder SupplierAlbina (Klamath Falls, OR)
RAP content (%)25 WMA AdditivesNo
Antistrip typeLime

Test Details

DIME Sample ID: 2026-05-18-74
DIME Test ID: 2026-05-18-74-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-06-30

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 05/26/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7330.6 grams
Mass of oven-dry sample in air for Sample 1: 1563.7 grams
Mass of container filled with the sample and water for Sample 1: 8260.2 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.466
Theoretical maximum density at 25°C (77°F): 2458.8 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmm=2.466

Test was verified on 6/30/2026